Back to dashboard

HeliosDose™

Models & Publications

HeliosDose is an analytical mission-planning and education model— not a Monte Carlo transport code and not for flight certification. The citations below document the physics and radiation-protection practice that shieldingEngine.ts and noaaFetch.ts approximate.

Model limits (what this surrogate claims)

  • Physics: analytical attenuation + soft build-up only — not Monte Carlo / HZETRN / GEANT4.
  • Use: education and conceptual mission planning — not flight certification or operational radiation protection. For absolute fidelity, prefer OLTARIS, ARRBOD, or peer institutional transport codes.
  • Risk factors: organ w_T, Q, ELR, and DDREF are NASA/ICRP-inspired approximations reduced to transparent planning numbers.
  • Flux provenance: UI labels clearly separate Live NOAA SWPC, synthetic Quiet/Moderate/Extreme scrubber scenarios, and Historical SPE reconstructions (scaled for the planning model — not archive playback).

1. Analytical shielding attenuation

Ambient dose versus areal density uses a planning surrogate

D(x) = D₀ · e−μx + B(x)

where x is areal density (g/cm²), μ is a spectrum-averaged mass attenuation (Al ≈ 0.045 cm²/g; HDPE ≈ 0.072 cm²/g), and B(x) is a soft secondary / build-up term that grows then saturates. Free-space ambient combines a GCR rate proxy (LEO vs deep space) with an SPE contribution scaled from GOES ≥10 / ≥100 MeV flux and alert level. This is intentionally simpler than full Boltzmann or Monte Carlo transport (e.g. HZETRN / GEANT4).

  1. [1]

    Wilson, J. W., et al. (1995). Issues in space radiation protection: galactic cosmic rays. Health Physics, 68(1), 50–58.

    https://doi.org/10.1097/00004032-199501000-00006

    Foundational framing for GCR shielding and hydrogenous materials versus aluminum.

  2. [2]

    Slaba, T. C., Blattnig, S. R., & Badavi, F. F. (2010). Faster and more accurate transport procedures for HZETRN. Journal of Computational Physics, 229(24), 9397–9417.

    https://doi.org/10.1016/j.jcp.2010.09.010

    Transport-code context HeliosDose deliberately does not implement; cited as the class of physics our exponential + build-up surrogate approximates.

  3. [3]

    Berger, M. J., et al. NIST XCOM: Photon Cross Sections Database. National Institute of Standards and Technology.

    https://www.nist.gov/pml/xcom-photon-cross-sections-database

    Mass-attenuation concept (μ) used in the planning form D(x) = D₀ e^{−μx} + B(x); HeliosDose uses spectrum-averaged μ for Al and HDPE, not energy-resolved cross sections.

2. Organ dose, tissue weights & quality factors

Attenuated ambient dose is inverted to organ absorbed dose via a body self-shield factor, then to equivalent dose with quality factors Q and to effective-dose contributions with tissue weights w_T inspired by ICRP Publication 103 and NASA / NCRP spaceflight organ tracking (active bone marrow, ocular lens, skin, CNS/brain). Lens is treated as a deterministic-limit organ (cataract), not via stochastic ELR.

  1. [1]

    ICRP (2007). The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Annals of the ICRP, 37(2–4).

    https://doi.org/10.1016/j.icrp.2007.10.003

    Tissue weighting factors w_T and equivalent-/effective-dose formalism that inspire HeliosDose organ inversion (e.g. active bone marrow w_T ≈ 0.12; skin w_T ≈ 0.01).

  2. [2]

    NCRP (2000). Radiation Protection Guidance for Activities in Low-Earth Orbit. NCRP Report No. 132. Bethesda, MD: National Council on Radiation Protection and Measurements.

    https://ncrponline.org/publications/reports/ncrp-reports-132/

    LEO protection practice and organ-dose emphasis (including skin and lens) underlying NASA-oriented planning tools.

  3. [3]

    NASA (2022). NASA Space Flight Human-System Standard, Volume 1: Crew Health. NASA-STD-3001 Vol. 1.

    https://www.nasa.gov/wp-content/uploads/2020/10/nasa-std-3001-vol-1-rev-b.pdf

    Crew health / radiation exposure context for SPE and GCR mission planning (not a certification claim for this app).

3. Excess lifetime risk & DDREF

Stochastic excess lifetime risk (cancer mortality) applies a sex- and age-modulated coefficient (~5%/Sv nominal) with a Dose and Dose-Rate Effectiveness Factor DDREF = 1.5 for cancer and 1.2 for a simple CNS performance-decrement proxy. These are BEIR-style / NASA risk-projection concepts reduced to transparent planning numbers — not individualized clinical risk assessments.

  1. [1]

    National Research Council (2006). Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2. Washington, DC: The National Academies Press.

    https://doi.org/10.17226/11340

    Excess lifetime risk and DDREF framing. HeliosDose uses a simplified ~5%/Sv sex-/age-modulated coefficient with DDREF_cancer = 1.5 and DDREF_CNS = 1.2.

  2. [2]

    Cucinotta, F. A., Kim, M.-H. Y., & Chappell, L. J. (2013). Space Radiation Cancer Risk Projections and Uncertainties — 2012. NASA/TP-2013-217375.

    https://three.jsc.nasa.gov/articles/TP_2013_Cucinotta.pdf

    NASA space radiation cancer risk projection concepts that motivate HeliosDose ELR outputs as educational estimates.

  3. [3]

    NCRP (2006). Information Needed to Make Radiation Protection Recommendations for Space Missions Beyond Low-Earth Orbit. NCRP Report No. 153.

    https://ncrponline.org/publications/reports/ncrp-report-153/

    Beyond-LEO risk and CNS concern context for deep-space / transit scenarios in the dashboard.

4. Live telemetry (NOAA SWPC)

When the browser can reach SWPC (CORS permitting), HeliosDose fetches GOES primary integral proton channels and the planetary Kp index to drive flux banners and quiet / elevated / storm alert levels. On network or CORS failure, a synthetic GOES-like series keeps the dashboard interactive; that fallback is labeled in the UI and is not observational data. Historical gallery events never replace the live poll — they only override the dose-engine inputs while charts remain labeled as reconstructions.

  1. [1]

    NOAA Space Weather Prediction Center. Space Weather Products and Services.

    https://www.swpc.noaa.gov/

    Operational space-weather source for live proton flux and geomagnetic activity when browser CORS permits.

  2. [2]

    NOAA SWPC. GOES Primary Integral Protons (1-day JSON).

    https://services.swpc.noaa.gov/json/goes/primary/integral-protons-1-day.json

    Endpoint used by HeliosDose for ≥10 / ≥50 / ≥100 MeV integral proton channels (pfu).

  3. [3]

    NOAA SWPC. Planetary K-index product.

    https://services.swpc.noaa.gov/products/noaa-planetary-k-index.json

    Endpoint used for the planetary Kp index that feeds storm / elevated / quiet alert levels.

5. Light validation vs published SPE doses

The dashboard “How does this compare?” panel places HeliosDose active bone-marrow equivalent dose for gallery reconstructions under a stated case (Al 5 g/cm² · Deep Space · 1-day SPE window) next to published BFO / effective-dose order-of-magnitude bands for August 1972, October 1989, and Bastille Day 2000.

Expect preserved event ranking and decade-scale proximity, not digit-level agreement. Full-event fluence transport, anatomic self-shielding, and quality/RBE conventions in the literature differ from HeliosDose’s scaled GOES-like fluxes and mean Q. Prefer range bands over false precision.

EventLit. BFO / E band (≈5 g/cm² Al)Primary sources
August 1972~400–700 mSvHoff 2002; Cucinotta 2010; Townsend 1991
October 1989~300–650 mSvHoff 2002; Parsons & Townsend; Townsend 1991
Bastille Day 2000~100–300 mSvHoff 2002; Hoff 2001 AIP
  1. [1]

    Hoff, J. L., Townsend, L. W., & Zapp, E. N. (2002). Space radiation protection: comparison of effective dose to bone marrow dose equivalent. Journal of Radiation Research, 43(Suppl.), S125–S128.

    https://doi.org/10.1269/jrr.43.S125

    Same-method BRYNTRN+CAM table for August 1972, October 1989, and July 2000 at Al 1–10 g/cm² — primary cross-event band source on the dashboard.

  2. [2]

    Cucinotta, F. A., et al. (2010). Space radiation risk limits and Earth–Moon–Mars environmental models. Space Weather, 8, S00E09.

    https://doi.org/10.1029/2010SW000572

    August 1972 King-spectrum organ doses and effective dose behind Al 5 and 20 g/cm² spheres (Table 6).

  3. [3]

    Townsend, L. W., et al. (1991). Interplanetary crew exposure estimates for the August 1972 and October 1989 solar particle events. Radiation Research, 126(1), 108–110.

    https://doi.org/10.2307/3578178

    BRYNTRN organ-dose comparison establishing Aug 1972 as more limiting than Oct 1989 for skin / lens / marrow.

  4. [4]

    Parsons, J. L., & Townsend, L. W. Estimates of Radiation Exposures to Crews on Missions in Cis-Lunar Space from the October 1989 Series of Solar Particle Events. Texas Tech University / related SPE dose tables.

    http://hdl.handle.net/2346/74193

    Cis-lunar Al and polyethylene organ / effective doses for the summed October 1989 series (incl. ≈5 and 20 g/cm²).

  5. [5]

    Hoff, J. L., Townsend, L. W., & Zapp, E. N. (2001). Interplanetary crew doses and dose rates for the July 2000 solar particle event. AIP Conference Proceedings, 552, 1217.

    https://doi.org/10.1063/1.1358075

    Bastille Day 2000 GOES-driven organ dose estimates behind aluminum — complements the 2002 cross-event table.

Disclaimer

Outputs are educational and conceptual mission-planning estimates. They must not be used for flight certification, crew medical decisions, or operational radiation protection. Prefer agency-validated transport and risk codes for engineering and flight work. Full terms: Education Disclaimer. Independent Scientific & Modeling Advisory is available for educational workshops and scenario framing — not clinical SaMD, flight certification, or NASA ops.

Return to HeliosDose dashboard